GRAPHTEC
Instrument products : DATA LOGGER / RECORDER
GRAPHTEC GL820
GRAPHTEC GL820
DATA LOGGER / RECORER
: Modular system allows expansion up to 200 channels
The standard configuration has 20 analogue input channels. It can be expanded up to 200 channels by adding optional 20 channelextension terminal kits.
item | Description | |
---|---|---|
Number of analog input channels | 20 ch, Expandable up to 200 ch by unit of 20 ch | |
External input output | Input *1 | Trigger or Sampling input 1ch, Logic or Pulse input 4 ch |
Output *1 | Alarm output 4 ch | |
Sampling interval | 10 ms to 1 h (in 10 ms to 50 ms, voltage only and limited channel), External | |
Time scale | 1 sec to 24 hour/division | |
Trigger function | Action | Start or stop capturing data by the trigger |
Source | Start: Off, Input signal, Alarm, External *1, Clock, Week or Time | |
Stop: Off, Input signal, Alarm, External *1, Clock, Week or Time | ||
Combination | OR or AND condition at the level of signal or edge of signal | |
Condition | Analog: Rising, Falling, Window-in, Window-out | |
Pulse: Rising, Falling, Window-in, Window-out | ||
Logic: Rising, Falling | ||
Alarm function | Detecting method | Level or edge of signal |
Condition | Analog: Rising, Falling, Window-in, Window-out | |
Pulse: Rising, Falling, Window-in, Window-out | ||
Logic: Rising, Falling | ||
Alarm output*1 | 4 channels, Output type: Open collector (pulled-up to 5 V by resistor 10 kΩ) | |
Pulse input function *1 | Accumulating count mode | Accumulating the number of pulses from the start of measurement Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S. |
Instant count mode | Counting the number of pulses per sampling interval Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M counts/F.S. |
|
Rotation count (RPM) mode | Counting the number of pulses per second and then it is converted to RPM Range: 50, 500, 5k, 50k, 500k, 5M, 50M, 500M rpm /F.S. |
|
Max. input pulse rate | 50k pulses/sec or 50k counts per sampling interval (16 bits counter is used) | |
Calculation function | Between channels | Addition, Subtraction, Multiplication and Division for analog input |
Statistical | Select two calculations from Average, Peak, Max., Min., RMS | |
Search function | Search for analog signal levels, values of logic or pulse or alarm point in captured data | |
Interface to PC | Ethernet (10 BASE-T/100 BASE-TX), USB (Full speed) | |
Storage device | Built-in Flash memory (2 giga-bytes), USB memory device *2 | |
Data saving function | Captured data | Direct saving of data into built-in Flash memory or USB memory device |
Others | Setting conditions, Screen copy | |
Ring capturing mode | Function: ON/OFF, Number of capturing point: 1000 to 2000000 (size of the capture data will be limited to 1/3 of available memory when in Ring Mode) | |
USB memory device emulation | USB Memory emulation mode (Transfer or delete the file in built-in memory) | |
Engineering scale function | Set based on the reference point of the scaled output and input signal for each channel (Voltage measurement: four points are necessary to scale the output, Temperature measurement: two points are necessary to scale the output). | |
Display | Size | 5.7 inch TFT color LCD (VGA: 640 x 480 dots) |
Formats | Waveform + Digital, Waveform only, Calculation + Digital, Expanded digital | |
Operating environment | 0 °C to 45°C, 5 % to 85 % RH (When operating with battery pack 0 °C to 40 °C, charging battery 15 °C to 35°C) |
|
Power source | AC adapter (100 V to 240 V, 50/60 Hz) DC power (8.5 V to 24 V DC, max. 26.4 V)*3, Battery pack*3 |
|
Power consumption | 32VA or lower (When operating with AC adapter, displaying LCD, charging battery pack) |
|
External dimensions (WxDxH) | approx. 232 x 152 x 50 mm | |
Weight | approx. 900 g (Excluding AC adapter and battery pack) |
Software specifications
Item | Description |
---|---|
Supported OS | Windows XP / Vista / 7 (32 bits and 64 bits edition) |
Functions | Control GL820, Real-time data capture, Replay data, Data format conversion |
GL820 setting control | Input settings, Memory settings, Alarm settings, Trigger settings |
Controlled units | Up to 10 units or 500 channels |
Captured data | Transfers data in real-time (in binary or CSV format), saved data in GL820 or the USB memory |
Displayed information | Analog waveforms, Logic waveforms, Pulse waveforms, Digital values |
Display modes | Y-T waveforms, Digital values, Report, X-Y graph (specified period of data, data reply only) |
Warning functions | Sends E-mail to the specified address when the alarms occur |
File format conversions | Converts the specified period data or all data to the CSV format (thinning function is available) |
Report functions | Creates the daily or monthly report automatically (can also export directly to Excel) |
Standard accessories
Item | Description | Quantity |
---|---|---|
AC adapter | 100 V to 240 V AC, 50/60 Hz (with specified type of power cord) | 1set |
CD-ROM | User’s manual (PDF format), Application software | 1piece |
Quick Start Guide | 1copy |
Analog input specifications
Item | Description | |||
---|---|---|---|---|
Type of input terminal | Screw terminal (M3 screw) | |||
input method | Scans by the photo-MOS-relay, all channels isolated, balanced input | |||
Measurement range | Voltage Temperature | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V, and 1-5 V /F.S. Thermocouple: K, J, E, T, R, S, N, and W (WRe5-26) |
||
Resistance Temperature Detectors (RTDs): Pt100, JPt100 (JIS), Pt1000 (IEC751) | ||||
Humidity | 0 to 100% (using humidity sensor (B-530 optional), power is supplied to only one sensor) |
|||
Filter | Off, 2, 5, 10, 20, 40 (moving average in selected number) | |||
Measurement accuracy *4 | Voltage | 0.1% of F.S. | ||
Temperature | Thermocouple | Measurement range | Measurement accuracy | |
R/S | 0 °C ≦ TS ≦ 100 °C 100 °C ≦ TS ≦ 300 °C R: 300 °C ≦ TS ≦ 1600 °C S: 300 °C ≦ TS ≦ 1760 °C |
±5.2 °C ±3.0 °C ±(0.05 % of reading +2.0 °C) ±(0.05 % of reading +2.0 °C) |
||
B | 400 °C ≦ TS ≦ 600 °C 600 °C ≦ TS ≦ 1820 °C |
±3.5 °C ±(0.05% of reading +2.0 °C) |
||
K | -200 °C ≦ TS ≦ -100 °C -100 °C ≦ TS ≦ 1370 °C |
±(0.05 % of reading +2.0 °C) ±(0.05 % of reading +1.0 °C) |
||
E | -200 °C ≦ TS ≦ -100 °C -100 °C ≦ TS ≦ 800 °C |
±(0.05 % of reading +2.0 °C) ±(0.05 % of reading +1.0 °C) |
||
T | -200 °C ≦ TS ≦ -100 °C -100 °C ≦ TS ≦ 400 °C |
±(0.1 % of reading +1.5 °C) ±(0.1 % of reading +0.5 °C) |
||
J | -200 °C ≦ TS ≦ -100 °C -100 °C ≦ TS ≦ 100 °C 100 °C ≦ TS ≦ 1100 °C |
±2.7 °C ±1.7 °C ±(0.05 % of reading +1.0 °C) |
||
N | 0 °C ≦ TS ≦ 1300 °C | ±(0.1 % of reading +1.0 °C) | ||
W | 0 °C ≦ TS ≦ 2000 °C | ±(0.1 % of reading +1.5 °C) | ||
Reference Junction Compensation (R.J.C.): ±0.5 °C | ||||
RTD | Measurement range | Measurement accuracy | ||
Pt100 | -200 °C to 850 °C (FS=1050 °C) | ±1.0 °C | ||
JPt100 | -200 °C to 500 °C (FS=700 °C) | ±0.8 °C | ||
Pt1000 | -200 °C to 500 °C (FS=700 °C) | ±0.8 °C | ||
A/D Converter | ΣΔtype, 16 bits (effective resolution: 1/40000 of measuring full range) | |||
Maximum input voltage | Between +/- terminal | 60 Vp-p | ||
Between channels | 60 Vp-p | |||
Between channels / GND | 60 Vp-p | |||
Withstand voltage | Between channels | 350 Vp-p (1minute) | ||
Between channels(-) / GND | 350 Vp-p (1minute) |
- *1
- Logic alarm cable (B-513) option is required.
Input signal of External sampling, Logic, Pulse; Maximum voltage: 24 V, Threshold: approx. 2.5 V, Hysteresis: approx. 0.5 V - *2
- Size of the USB memory device is unlimited. Maximum file size is limited to 2 GB
- *3
- DC drive cable (B-514) or battery pack (B-517) option is required.
- *4
- Subject to the following conditions;
Item | Model number | Remarks |
---|---|---|
Logic alarm cable |
|
2m long (no clip on end of cable) |
DC drive cable |
|
2m long (no clip on end of cable) |
Battery pack |
|
1piece (7.4V 2200mAh, 17Wh) |
Humidity sensor* |
|
3m long (with power plug) |
Extension terminal base kit |
|
Terminal base, cable |
20ch extension terminal set |
|
Terminal base, Terminal unit (20ch), fixing plate |
Logic alarm cable (B-513) |
DC drive cable (B-514) |
Battery pack (B-517) |
Humidity sensor (B-530)* |
Extension terminal base kit (B-537) |
20ch extension terminal set (B-538) |