TDK LAMBDA
HWS-P SERIES |
Single output AC-DC converter 300- 600 |
|||
---|---|---|---|---|
|
■Features
- Up to 3 times peak current.
- High power in compact size.
- Low acoustic noise due to automated control fan.
- Follow HWS series concept.
-
Ideal for drive line load due its high reliability and easy-to-use.
■Specifications
Model |
HWS300P |
HWS600P |
||||||
---|---|---|---|---|---|---|---|---|
Output voltage |
24V |
36V |
48V |
24V |
36V |
48V |
||
Max. output power |
Average current |
12.5A |
8.4A |
6.3A |
25.0A |
16.7A |
12.5A |
|
Peak current |
100V Input |
21.0A |
14.0A |
10.5A |
40.5A |
27.0A |
20.0A |
|
200V Input |
42.0A |
28.0A |
21.0A |
83.0A |
55.5A |
41.5A |
||
Max. output power |
Average power |
300W |
302W |
302W |
600W |
601W |
600W |
|
Peak power |
100V Input |
504W |
504W |
504W |
972W |
972W |
960W |
|
200V Input |
1008W |
1008W |
1008W |
1992W |
1998W |
1992W |
||
Input voltage range |
AC85~265V or DC120~330 (47~63Hz) |
|||||||
Operating ambient temperature |
-10℃~+70℃ ( -10℃~+50℃:100%、+70℃:50% ) |
|||||||
EMI/EMS |
Conforms to VCCI class B, EN55011/EN55022 class B |
|||||||
Safety standards |
UL60950-1、EN60950-1、CSA60950-1(C-UL):Excluding DC input EN50178(OVⅡ), DENAN (100VACinput only) |
|||||||
Cooling |
Forced air with built-in fan (Automated temperature control fan) |
|||||||
Dimensions:W x H x D mm. |
61×82×165 |
100×82×165 |
The above contents may be changed without prior notice