HWS-P SERIES |
Single output AC-DC converter 300- 600 |
|||
|---|---|---|---|---|
|
||||
■Features
Up to 3 times peak current.
High power in compact size.
Low acoustic noise due to automated control fan.
Follow HWS series concept.
Ideal for drive line load due its high reliability and easy-to-use.
■Specifications
Model |
HWS300P |
HWS600P |
||||||
|---|---|---|---|---|---|---|---|---|
Output voltage |
24V |
36V |
48V |
24V |
36V |
48V |
||
Max. output power |
Average current |
12.5A |
8.4A |
6.3A |
25.0A |
16.7A |
12.5A |
|
Peak current |
100V Input |
21.0A |
14.0A |
10.5A |
40.5A |
27.0A |
20.0A |
|
200V Input |
42.0A |
28.0A |
21.0A |
83.0A |
55.5A |
41.5A |
||
Max. output power |
Average power |
300W |
302W |
302W |
600W |
601W |
600W |
|
Peak power |
100V Input |
504W |
504W |
504W |
972W |
972W |
960W |
|
200V Input |
1008W |
1008W |
1008W |
1992W |
1998W |
1992W |
||
Input voltage range |
AC85~265V or DC120~330 (47~63Hz) |
|||||||
Operating ambient temperature |
-10℃~+70℃ ( -10℃~+50℃:100%、+70℃:50% ) |
|||||||
EMI/EMS |
Conforms to VCCI class B, EN55011/EN55022 class B |
|||||||
Safety standards |
UL60950-1、EN60950-1、CSA60950-1(C-UL):Excluding DC input EN50178(OVⅡ), DENAN (100VACinput only) |
|||||||
Cooling |
Forced air with built-in fan (Automated temperature control fan) |
|||||||
Dimensions:W x H x D mm. |
61×82×165 |
100×82×165 |
||||||
The above contents may be changed without prior notice